Retroreflective sensor RLK39-54-Z/31/40a/116
Glare protected with polarization filter
Visible red light
Light/dark ON, switchable
Timer function
Degree of protection IP67
產(chǎn)品闡述
Retroreflective sensor for standard applications, polarization filter, detection range 7 m, red light, timer function, sensitivity adjuster, light/dark on, relay contact output, terminal compartment
General specifications | ||
---|---|---|
Effective detection range | 0 ... 7 m | |
Threshold detection range | 9 m | |
Light source | LED red | |
Light type | modulated visible red light | |
Polarization filter | yes | |
Functional safety related parameters | ||
MTTFd | 803 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
Function indicator |
LED yellow: switching state LED red: pre-fault indication |
|
Control elements | Sensing range adjuster, light-on/dark-on changeover switch | |
Control elements | switch for timer function | |
Electrical specifications | ||
Operating voltage |
12 ... 240 V DC 24 ... 240 V AC (50 ... 60 Hz) |
|
Output | ||
Switching type | light/dark on | |
Signal output | 1 relay output | |
Compliance with standards and directives | ||
Directive conformity | EMC Directive 2004/108/EC | |
EMC Directive 2004/108/EC | EN 60947-5-2:2007+A1:2012 IEC 60947-5-2:2007+A1:2012 | |
Standard conformity | ||
Product standard |
EN 60947-5-2:2007 IEC 60947-5-2:2007 |
|
Approvals and certificates | ||
EAC conformity |
TR CU 020/2011 TR CU 004/2011 |
|
Approvals | CE | |
Mechanical specifications | ||
Housing width | 25 mm | |
Housing height | 64 mm | |
Housing depth | 75 mm | |
Degree of protection | IP67 | |
Connection | terminal compartment PG9, ≤ 2.5 mm2 | |
Material | ||
Housing | PBT | |
Optical face | PMMA |